Washing machine - How to replace the temperature probe (1)
Issue
How to replace the temperature probe
Applies to
- Washing machine
Resolution

Refer always to your product’s user manual safety information before any repair or maintenance operation. https://www.electrolux.com/support/user-manuals/

WARNING! RISK OF ELECTRIC SHOCK
Before any repair or maintenance operation, deactivate the appliance and disconnect the mains plug from the socket.


WARNING! RISK OF INJURY

Always take care when moving appliances. For heavy appliances it's safest for two persons to move it. Always use safety gloves and safety footwear. Wear safety gloves at all times to protect from cuts from sharp edges.

WARNING! RISK OF EYE INJURY

Wear safety glasses if you perform maintenance or repair work involving springs.

WARNING! RISK OF PINCHING

Wear safety glovesif you perform maintenance or repair work involving belts.

WARNING! CHOKING HAZARD
Small parts not for children under 3 years. Keep all small parts and packaging out of reach of children.
Only adults should use or install the product.
Before any maintenance operation, turn off water supply to the appliance. Always empty the appliance of all the water. Any maintenance should be carried out with the appliance standing upright. Residual water could damage electronics if the appliance is placed on any of its sides.
Make sure to use the product only for its designated purpose and verify that it is a compatible part for the intended product.
Do not use or install the product if damaged.
Please note that self-repair or nonprofessional repair can have safety consequences if not done properly and might void the warranty. Possessing the necessary know-how is essential.
HOW TO REPLACE THE TEMPERATURE PROBE
1. Unscrew the two 8mm screws on the back of the washing machine lid and slide back to release.



2. Unscrew and remove the inlet hose (NOTE: Water must be turned off, ensure you have something to catch any residual water in the hose). Replace the gasket in the inlet hose with the one supplied with the valve.

3. Use a small flat blade screwdriver to carefully prise open the clips on either side of the valve housing.

4. Use a small flat blade screwdriver to lever out the screw cover on either side of the washing machine at the bottom.


5. Unscrew the two 8mm screws behind the side screw covers and the two 8mm screws on the back panel of the washing machine.


6. Using a flat bladed screwdriver carefully prise the valve and valve connector away from its housing.

7. Unscrew the 8mm screw from the back panel of the washing machine to the ventilator.

8. Slide the back panel away from the crossbar, then remove fully, lifting the panel over the drain hose. (NOTE: When reinstalling ensure that the back panel is completely clipped back into position before screwing into place).



9. Carefully unclip the wiring connectors from the temperature probe. Be careful not to damage the wiring connector.

10. Carefully pull the temperature probe out from the condenser hose.


11. When assembling, repeat steps in reverse order.